On the K4A8G165WC-BCTD, changing BA still requires tCCD_L when BG0 is unchanged. This example covers two ordinary BL8 reads in the same rank. The target rows must already meet the required activation timing. At 0.750 ns per CK, the tCCD-only minimum is seven CK within one group. Across groups, it is four CK. Decode BG0 and BA in the issued-command trace.
Identify the bank group from BG0
The K4A8G165WC-BCTD is an 8 Gb DDR4 component, organized as 512M ×16, in a 96-ball FBGA package. Its BCTD speed bin is DDR4-2666. This x16 device has two bank groups, each containing four banks.
BG0 selects the group. BA1 and BA0 select the bank within it. Decode any combined bank number using the controller documentation. Record the rank, BG0 and BA for both reads.
| Consecutive read addresses | Bank group relationship | Check |
|---|---|---|
| BG0=0, BA=00 → BG0=0, BA=01 | Different banks in one group | tCCD_L |
| BG0=0, BA=00 → BG0=1, BA=00 | Same BA in different groups | tCCD_S |
Check the running device geometry and address map. Interleaving or remapping can change which group a processor address reaches. Adjacent processor addresses do not establish the group relationship. Verify the selected device width and group count in the active controller configuration.
Convert the timing limit to DRAM clock cycles
Table 53 in the Samsung K4A8G165WC data sheet specifies tCCD_L as max(5 CK, 5 ns) for DDR4-2666. Both limits apply. The tCCD_S minimum is four CK cycles. DDR transfers data on both edges, so 2666 MT/s corresponds to DRAM CK near 1333 MHz.
At 0.750 ns per CK, six cycles take 4.50 ns and fail the 5 ns limit. Seven take 5.25 ns. Seven CK is therefore the minimum whole-cycle interval for tCCD_L in this example.
| Two reads within one rank | Example interval | tCCD result only |
|---|---|---|
| BG0=0 → BG0=0 | 4 CK, 3.00 ns | Below the same-group minimum |
| BG0=0 → BG0=0 | 7 CK, 5.25 ns | Meets the same-group minimum |
| BG0=0 → BG0=1 | 4 CK, 3.00 ns | Meets the different-group minimum |
Measure from one issued RD command to the next. CL19 describes read latency. It does not set tCCD_L. Check the controller field's encoding and clock domain before programming a value. At another operating rate, use that speed column and the data-sheet rounding rules. The table assumes ordinary BL8 reads in one rank, with target rows activated under the required timing. These are tCCD-only limits. Controller modes and other command constraints can require longer intervals.
Verify the issued commands with two address pairs
Create two address pairs under the same controller and firmware settings. For the first, hold BG0 constant and change BA. For the second, change BG0. Resolve both pairs through the active memory map. Use a supported DRAM command trace, controller simulation or validation interface.
Capture each RD command's timestamp, rank, BG0, BA and column. Recover the active row from that bank's ACT history. Convert controller cycles to DRAM CK when necessary. Application request times are insufficient: cache hits may produce no DRAM read, and queues can delay or reorder commands.
Inspect a short sequence by hand. Confirm the rank and the preceding ACT timing. If a same-group interval appears too short, recheck group decoding and the clock domain. Then inspect the configured device geometry and scheduler timing. Check the order of intervening commands before changing a timing field.
Use distinct known patterns in a reserved test region or simulation and verify the readback. Match each request to its issued RD. Retain surrounding commands if traffic is interleaved. Simplify the workload if the intended pair cannot be identified.
A gap longer than four CK does not by itself show a fault. Row state, refresh or an unready request can delay the second RD. Compare command spacing rather than application throughput. If tCCD passes but data errors remain, continue initialization, training, signal integrity and power checks.
Capture the settings and traces for sample approval
Keep both traces with the exact ordering code, board revision, controller/IP revision and firmware configuration. Record the operating rate, CK period, burst mode, decoded addresses and measured intervals. Include the separate data integrity result.
Cross-check the sample label against the manufacturer ordering table. The guide to checking DRAM part numbers helps with markings. Retain the suffix so the timing result remains linked to the evaluated part.
Use the Samsung part directory to locate candidates. Compare organization, bank groups, pinout, power and timing at the target operating point. Repeat both read pairs after a part, board or firmware change. Recheck the configuration loaded for the candidate before accepting the result.
For a K4A8G165WC-BCTD request, attach the board revision, operating data rate and both bank-group traces. Use the same controller baseline to compare candidate packages, device organization and command intervals. Send SUNTEC the full ordering code, quantity and sample acceptance conditions for a quote.
Prepared by the SUNTEC Technical Team at Suzhou SUNTEC Electronics Co., Ltd.