Keep boot selection separate from later vector-table configuration. Keep both separate from failures after main.

1. Keep the image and debug conditions consistent

Start with the exact STM32H743VIT6 project. Save the board revision, full device marking, tool versions, and the image actually programmed. Keep the linker map and startup files with that build. Changing the source code or using different debug and release images can invalidate the comparison.

Record what the debug session does before Run. Include programming, reset mode, initialization scripts, and any explicit register or execution-state setup. Do not assume every debugger performs these actions. We need the actual configuration, not a general claim that debugging changes the result.

Define the failure in observable terms. Is the expected application never reached? Does startup stop before main? Does main run without the expected output? Save that distinction before changing boot options or firmware. It determines which evidence we need next.

2. Separate debugger Run, NRST, and power-on tests

Compare events individually. ST AN4938 Rev 7 describes reset sources and the debug connection. Clicking Run, applying NRST, and restoring board power are different test conditions.

Record probe connection and power sources for each test. A board switch alone does not document the voltage at the device.

Table 1 Keep the startup evidence separate
EventWhat to recordWhat it does not establish alone
Run after programmingActual image, debug script, reset action, and starting halt pointThe standalone startup path without the debugger
External NRSTReset event, supply and external connections, startup behaviorThe outcome of a power-on test
Power cycleDevice-side supply and reset behavior plus probe and USB connectionsThat a board-switch action caused the intended device reset

For a power-on test, establish the actual power sequence and reset behavior at the device against its applicable electrical requirements. We do not prescribe a universal off-time or reset pulse. Keep the debugger-assisted result and the standalone result as separate records. This gives the boot-target check a reproducible starting point.

3. Check the effective H743 boot target

BOOT0 alone is not a complete address check. DS12110 Rev 11 describes boot selection using the boot pin and BOOT_ADDx options. AN4938 Table 2 associates BOOT0 low with BOOT_ADD0 and high with BOOT_ADD1.

Read the actual option settings and record BOOT0 under the failing reset condition. Protection or secure-access settings can alter the documented boot behavior. Interpret the selection under the applicable device conditions.

Compare the resulting target with the intended application location. Factory-default addresses are not evidence of the options currently stored in a device. If execution enters system memory, investigate that selection before changing application vector settings. Do not infer the selected boot memory from a programming-success message.

Our STM32F103C8T6 BOOT0 and BOOT1 guide covers a different device. It does not supply H743 option settings. Retain the observed H743 boot target as this section’s result. We use it to inspect the matching image next.

4. Check the image vectors and first stopping point

Compare the programmed range with the linker output and intended startup location. ST’s boot-process FAQ explains the initial stack value and reset-handler entry in the vector table. Check those entries against this build’s memory layout and startup code. Verification of some programmed bytes cannot establish that the intended startup data is present at the selected target.

PM0253 Rev 6 describes vector-table relocation through VTOR. Keep that later software configuration separate from selection of the boot target. Inspect the project’s actual startup and system-initialization code. A forum instruction to enable USER_VECT_TAB_ADDRESS is not a universal H743 repair.

Table 2 Use the earliest confirmed execution point
Observed stateNext checkRecorded conclusion
Expected application entry not confirmedRecheck the boot target and programmed image locationEntry remains unconfirmed; no specific cause established
Reset_Handler reached but main not reachedLocate the earliest failing startup or initialization stepRecord the specific stopping point and its state
main reached, then execution stopsLocate the actual stalled or faulting positionDo not classify this simply as never entering the application
Application runs but output is missingCheck the output path and application stateMissing output alone does not establish that the CPU never started

If you reconnect a probe to inspect a failure, record its reset and halt behavior. The act of attaching may change the observed state. Treat that observation accordingly. Do not label a later debugger-controlled state as untouched evidence of the earlier power-on failure.

5. Record the standalone retest result

Change one justified item at a time, then repeat the defined reset and standalone power-on tests. Keep the image identifier, options readback, probe state, reset event, and execution result together. A temporary success after a debugger session does not close the original failure.

For component evaluation, our STM32 series selection guide adds family context. The startup decision still belongs to the exact device, board, and firmware. Record remaining failures explicitly. This is a diagnostic workflow, not a report of a tested VIT6 board or a guaranteed repair.

Include the full STM32H743VIT6 part number, board revision, image identifier, and failing startup condition in the project brief. Compare candidate parts against the same boot configuration, memory layout, and firmware requirements. For a SUNTEC quotation, provide the part number, quantity, and the integration conditions that still need clarification.

Prepared by the SUNTEC Technical Team at Suzhou Shengyatai Electronics Co., Ltd.