1. Define the erase operation and its complete target range
Start with the W25Q128JVSIQ awake and its supply stable. The excluded range is the whole sector or block being erased. It is not just the address supplied with the command. Record the actual opcode and the aligned first and last address of that erase unit.
| Erase operation | Target granularity | Erase suspend eligibility |
|---|---|---|
| Sector Erase 20h | 4KiB sector / 4096 bytes | Supported during an active sector erase |
| Block Erase 52h | 32KiB block / 32768 bytes | Supported during an active block erase |
| Block Erase D8h | 64KiB block / 65536 bytes | Supported during an active block erase |
| Chip Erase C7h or 60h | Entire chip | Not supported; 75h is ignored |
Winbond's W25Q128JV datasheet Revision M, sections 8.2.19 and 8.2.20, defines the suspend and resume conditions. Similar names do not establish the same voltage or suspend requirements. Use the JV and JW voltage and interface checks for that selection check. Confirm suspend behavior in each exact part's datasheet.
Keep the current erase operation in the driver's state record. A BUSY flag cannot identify which region is affected. This step produces a known opcode and excluded address interval for the suspend check.
2. Confirm that the Flash has entered erase suspend
Sending 75h does not prove that suspension succeeded. For a known sector or block erase in progress, the Flash accepts 75h when SUS is 0 and BUSY is 1. It ignores the command when SUS is already 1 or BUSY is 0.
Read Flash Status Register-1 with 05h for BUSY and Status Register-2 with 35h for SUS. These are Flash bits, not the controller's BUSY indication. For a conservative check, wait at least 20 microseconds from the end of the 75h frame, then read both registers. This uses Rev M's maximum tSUS latency. It is not an AC minimum or each suspend's exact duration.
| Flash BUSY and SUS | Interpretation | Next action |
|---|---|---|
| BUSY 1 and SUS 0 | The known erase is still active | Do not start the requested array read |
| BUSY 0 and SUS 1 | The operation is suspended | Check the complete read range against the erase target |
| BUSY 0 and SUS 0 | No suspended operation is indicated | Check whether erase completed or suspend was not accepted |
This table assumes no concurrent program activity. It is not a complete decoder for every operation combination. Proceed with a suspend-window read only after the state and target agree. Keep both register values and their read times with the erase record.
3. Check every address that the read can touch
Use a confirmed Standard SPI 03h read for the basic check. First validate the start address and length against device capacity. Do not use an overflowing range or assume wraparound. Compare the complete read span with the suspended erase target. Starting outside is insufficient if the requested length crosses into it. Every requested address must remain outside that target.
The application's requested bytes may not describe every controller access. Read the exact MCU and controller documentation for instruction fetches, execute-in-place operation, cache fills, and prefetch. Determine whether they can generate additional reads. Their actual address ranges must also avoid the suspended target.
The Flash driver must coordinate those request sources throughout the suspend window. If the access range cannot be established, do not approve that path merely because the Flash supports suspend. Use the indirect and memory-mapped read checks to investigate that separate controller path.
Rev M prohibits Write Status Register 01h and the listed erase instructions during Erase Suspend. Our read-only workflow schedules no additional writes. Record the allowed read intervals and the request sources checked before moving to resume.
4. Resume the erase and verify its actual completion
Resume continues the suspended erase; it does not finish it immediately. The Flash accepts 7Ah when SUS is 1 and BUSY is 0. SUS then clears. Rev M allows up to 200 ns for BUSY to return to 1. An immediate BUSY 0 reading cannot prove completion. The 200 ns limit concerns status reassertion, not remaining erase time. Allow the documented BUSY reassertion interval after the 7Ah frame. Then monitor the known erase until BUSY and SUS are both 0. Verify the target's expected erased contents.
A new 75h must also respect the minimum tSUS interval after the preceding 7Ah. This is a resume-to-next-suspend spacing requirement. It is distinct from the maximum suspend latency after 75h. Do not turn either value into a universal erase-completion delay.
Unexpected power loss releases the suspend state and clears SUS. Data in the affected sector or block may be corrupted. Resume is ignored after that interrupted suspend. On restart, a cleared status bit cannot prove that the previous erase completed. Route the target through the project's recovery and data-validation procedure.
Save the opcode, target interval, read ranges, status sequence, timing, and power conditions with the final validation result.
For a W25Q128JVSIQ requirement, record the erase opcode, target range, controller, and reads needed during suspension. Check candidate parts against their documented suspend restrictions, timing, voltage, and system access requirements. For a SUNTEC quotation, provide the complete ordering code, quantity, and confirmed operating requirements.