An Analog Devices DS18B20 that keeps reading 85°C may be returning its power-on temperature value after startup or a power interruption, before a fresh conversion has completed. Check the conversion command, completion time and supply at the sensor before replacing it. The value alone does not prove a fault: 85°C can also be a real measurement.

What does an 85°C reading mean on a DS18B20?

The DS18B20 datasheet, Rev. 6, specifies +85°C as the temperature register's power-on value, represented by 0550h. A completed temperature conversion updates the temperature register. Read Scratchpad (BEh) reads stored data; it does not start a new measurement.

An initial 85°C reading therefore calls for a conversion check. If temperatures look normal and later return to 85°C, also investigate whether a supply interruption has reset the sensor. Neither pattern identifies the cause by itself, so compare the raw data with the command sequence and power observations.

A presence pulse confirms that a device has responded on the bus. It does not prove that a temperature conversion has completed or that the device has adequate power during conversion.

How to verify a complete temperature conversion

Trace the complete measurement cycle in the temperature-reading routine:

  1. Reset the 1-Wire bus, check for a presence pulse and address the intended sensor using its ROM code.
  2. Send Convert T (44h) to start a temperature conversion.
  3. Allow conversion to complete using the method required by the active resolution and power mode.
  4. After conversion completes, reset the bus again, address the same sensor and send Read Scratchpad (BEh), then read all nine bytes, including the CRC byte.

The datasheet specifies the following maximum conversion times under its stated operating conditions. These are timing limits, not measured durations for every sensor.

9-bit10-bit11-bit12-bit
93.75 ms187.5 ms375 ms750 ms

If you use a fixed delay, wait at least the maximum conversion time listed for the resolution actually read back from the sensor. Although the datasheet lists a 12-bit power-on default, a configuration previously saved to EEPROM is recalled at power-up. Do not assume the shorter 9-bit interval applies.

With external power, the master can issue read time slots directly after Convert T (44h): the sensor returns 0 while busy and 1 when conversion is complete. Check this status before starting a new bus reset and ROM addressing sequence. Parasite-powered operation requires a different approach because the bus must provide conversion power.

For diagnosis, log when 44h is sent, how completion is determined and when BEh starts the scratchpad read. Record the power mode and resolution with those timestamps. Distinguish a completion status returned by an externally powered sensor from the end of a fixed wait; calling a temperature-reading function alone does not prove that a new conversion has completed.

Check power while the sensor is converting

For externally powered operation, check VDD relative to GND at the DS18B20 itself. The specified external supply range is 3.0–5.5 V. A normal voltage measurement at the controller's supply output, or at the sensor while idle, does not confirm adequate voltage at the sensor during conversion. Inspect voltage drop, intermittent connections and the ground connection.

In parasite-power mode, VDD is connected to ground and the device draws power from DQ. The ordinary bus pull-up resistor cannot replace the strong pull-up required during conversion. Enable that strong pull-up within 10 μs after transmitting the complete Convert T (44h) command and maintain it for the entire conversion period.

No other 1-Wire activity can take place while the strong pull-up supplies conversion power. Do not poll for conversion completion while the strong pull-up is active, or assume that fitting a smaller pull-up resistor provides the required supply.

For a DS18B20 sensing project, record the full order code, package, power mode and configured resolution. Check candidate parts or probe assemblies for the required interface, wiring and power requirements during conversion before treating them as interchangeable. To request a quote from SUNTEC, submit the part number, quantity and required delivery date through the website's part inquiry form.